Product introduction
Detect the fire resistance of cables for wiring or power grids, burn in flames not lower than 750°C and 830°C, and detect cables to maintain the integrity of the circuit. The complete set of tests includes the fire resistance test methods specified by BS 8491.
Technical parameters
1. Separate design of gas and test test bench and circuit and
console, safe and reliable;
2. Standard sample support frame, metal ring and support frame are
all well grounded;
3. The gas system is composed of a pressure reducing valve, a
pressure gauge, a mass flow meter, a Venturi mixer and a burner;
4. Imported gas pressure reducing valve provides a stable outlet
pressure of 0.1Mpa±3Pa;
5. Imported pressure gauge, providing 0-200kPa pressure display;
6. Imported mass flow meter, accuracy of ±1%, repeatability
<0.2%Rd.;
7. Imported venturi mixer, the mixing ratio is adjustable;
8. The standard recommends American AGF burner, model: 1857B;
9. Equipped with flame calibration device, using American OMEGA
1.5mm K type thermocouple, the calibration result is directly
displayed on the software;
10. The flame time can be set and automatically cut off, without
human monitoring, with ignition device;
11. The voltage of the transformer is adjustable, can adapt to the
working voltage of different products, and can provide sufficient
test voltage when the test current leaks;
12. Provide 5 test voltages, transformers and fuses in series, and
provide circuit breakers to protect each test circuit;
13. The test circuit is connected in series with the bulb, and the
sound and light alarm are provided to provide intuitive judgment
instructions;
14. The standard requires spray device and mechanical impact
device, and the test procedure is automatically controlled;
15. The standard requires spray device and mechanical impact
device, and the test procedure is automatically controlled;
16. 15-inch industrial touch control computer, easy to operate and
use;
17. Standard operating software, with functions such as test
control, data recording, data processing, and report output.
Main equipment module
1. The main console, electrical control, and software acquisition
integrated control cabinet;
2. Wall-mounted control box is used for different test methods to
choose different modes;
3. Fire-resistant test platform for N-type cable testing;
4. Fire-resistant percussion spray integrated test platform for NJ
cable testing;
5. Fire-resistant percussion jet integrated test platform for NS
type cable testing.
What is fire resistance cable?
The definition of a fire-resistive or fire-rated cable is a cable
that will continue to operate in the presence of a fire. This is
commonly known as a circuit integrity (CI) cable and is 2-hour
fire-rated. ... This 2-hour fire-resistive cable is designed for
emergency power circuits for fire pumps and emergency generators.
What is a fire test?
A fire test can also mean an ad hoc test performed to gather information in oder to understand a specific hazard, such as a consturction or storage configuration.
![]() |